Calculate the reverberation time of a meeting room

Room

Room use
Dimensions
Volume105 m³Floor area35 m²Wall area72 m²
Surfaces
Floor
Walls
Ceiling
Furnishings

Nothing added yet.

An empty room reverberates the most. Add people, furniture or windows for a realistic picture.

Current state1.28s
With measuresNo measures yet
0.71 s above targetToo reverberant. Add absorbers.
Reverberation time by frequency
Terms of use

Measures

No measures yet

Add acoustic products and see the effect instantly.

Meeting rooms fall under DIN 18041 room group A: the target value depends on the volume, every octave band has to stay inside the tolerance band. The calculator starts with 105 m³ (Meeting, conference or convention room), target value 0.48 s (0.38 to 0.57), and suggests the area needed from 2,004 products with measured data. Video conferencing has a shorter target value.

Target values by standard

Target values for meeting and conference rooms in three room sizes. The target value applies as the average of 500 and 1,000 Hz.

StandardUse60 m³100 m³200 m³
DIN 18041, group ADIN 18041:2016-03Meeting, conference or convention room (A3)0.40 s (0.32 to 0.48)0.47 s (0.38 to 0.56)0.57 s (0.45 to 0.68)
OIB guideline 5OIB-Richtlinie 5:2023-05Classroom, meeting room, media room (Kommunikation)0.40 s (0.32 to 0.48)0.47 s (0.38 to 0.56)0.57 s (0.45 to 0.68)
BB93, schoolsBuilding Bulletin 93 (2015)Meeting or video-conference roomat most 0.80 sat most 0.80 sat most 0.80 s
SS 25268, offices (Sweden)SS 25268:2023Meeting and conference room (by volume)at most 0.50 sat most 0.50 sat most 0.50 s
BR18, schools, day care, offices (Denmark)BR18 (2018) mit Vejledning om lydforholdSingle office, meeting room (SBi 216)at most 0.60 sat most 0.60 sat most 0.60 s
SFS 5907, classes A1 and A2 (Finland)SFS 5907:2022Meeting or retreat room (A2)0.60 s (0.50 to 0.70)0.60 s (0.50 to 0.70)0.60 s (0.50 to 0.70)
NBN S 01-400-2, schools (Belgium)NBN S 01-400-2:2012Office, staff room, meeting roomat most 1.00 sat most 1.00 sat most 1.00 s
PN-B-02151-4, reverberation and speech intelligibility (Poland)PN-B-02151-4:2015-06Conference room, courtroom, auditorium (by volume)at most 0.80 sat most 0.80 sat most 0.80 s
LEED v4, acoustic performanceLEED v4 / v4.1 EQ Credit: Acoustic PerformanceConference or teleconference roomat most 0.60 sat most 0.60 sat most 0.60 s

Typical measures

  • Acoustic ceiling or one large ceiling raft above the table.
  • Wall absorbers on the end wall behind the display and on one long wall.
  • For video conferencing, absorbers near the camera and microphone.
  • Curtains in front of glass help at high frequencies, the low frequencies need thick absorbers.

Ceiling rafts and wall absorbers with measured data

All products in the search

Frequently asked questions

What reverberation time does a meeting room need?

Under DIN 18041 volume-dependent, for around 100 m³ about 0.5 s, averaged over 500 and 1,000 Hz, with a tolerance band of plus or minus 20 percent between 250 and 2,000 Hz.

Does a different value apply to video conference rooms?

Yes, DIN 18041 lists video conferencing as its own use with a shorter target value, because microphones pick up reverberation more strongly than the ear. Switch the use in the calculator.

How many absorbers does a room of 100 m³ need?

Around 15 to 25 m² of equivalent absorption area in addition to carpet and furniture, so one ceiling raft over half the ceiling or a covered end wall plus a smaller raft.

Other room types