Calculate the reverberation time of a practice or waiting room

Room

Room use
Dimensions
Volume84 m³Floor area30 m²Wall area62 m²
Surfaces
Floor
Walls
Ceiling
Furnishings

Nothing added yet.

An empty room reverberates the most. Add people, furniture or windows for a realistic picture.

Current state2.46s
With measuresNo measures yet
1.61 s above targetToo reverberant. Add absorbers.
Reverberation time by frequency
Terms of use

Measures

No measures yet

Add acoustic products and see the effect instantly.

Waiting, treatment and consulting rooms fall under DIN 18041 room group B with a minimum absorption per cubic metre, so conversations stay intelligible. The calculator starts with 84 m³ (Waiting, treatment or patient room, consulting room), requirement at most 0.85 s, and suggests wipeable absorbers from 2,004 products with measured data.

Requirements by standard

Requirements for practice and waiting areas in three room sizes. DIN 18041 sets a minimum absorption via A/V, France names its own values for healthcare buildings.

StandardUse50 m³100 m³200 m³
DIN 18041, group BDIN 18041:2016-03Waiting, treatment or patient room, consulting room (B3)at most 0.85 sat most 0.85 sat most 0.85 s
Arrêté du 25 avril 2003, healthcareArrêté du 25 avril 2003Ward, care, examination or consulting room, medical officeat most 0.80 sat most 0.80 sat most 0.80 s
BR18, schools, day care, offices (Denmark)BR18 (2018) mit Vejledning om lydforholdExamination or treatment room (SBi 216)at most 0.60 sat most 0.60 sat most 0.60 s
PN-B-02151-4, reverberation and speech intelligibility (Poland)PN-B-02151-4:2015-06Consulting or treatment roomat most 0.80 sat most 0.80 sat most 0.80 s

Typical measures

  • Wipeable acoustic ceiling in the waiting room and at reception.
  • Acoustic pictures in the waiting area so conversations at the desk are not overheard.
  • In the treatment room, partial coverage of the ceiling is usually enough.
  • Calculate corridors and staircases separately.

Wipeable ceiling and wall absorbers with measured data

All products in the search

Frequently asked questions

What reverberation time applies in a medical practice?

DIN 18041 assigns waiting and treatment rooms to room group B3: A/V from 0.20 m⁻¹ at room heights up to 2.5 m. For 85 m³ that is around 17 m² of absorption area, so about 0.6 to 0.7 s.

Which absorbers are hygienically acceptable?

Closed, wipeable surfaces: acoustic ceilings with a hygienic coating, absorbers with a fleece facing, acoustic pictures with a disinfectable cover.

How do I protect discretion at reception?

Absorption lowers the level, but does not replace shielding. What works is the combination of an absorbing ceiling, wall absorbers behind the desk and distance to the waiting area.

Other room types

Formulas, DIN 18041 and worked example on the calculator page