MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 214

Nagelsturz + Eichler NE-Standard panel ceiling Type 110/15

NE-Standard panel ceiling – Type 110/15

PTB reference data

Original description

Nagelsturz + Eichler NE-Standard panel ceiling Type 110/15

Material properties

Manufacturer: Nagelsturz + Eichler GmbH & Co KG
Thickness: 20.5 mm
Perforation: 18%
Hole size: 2 mm
Backing: 20 mm mineral fiber backing
Surface: 0.5 mm thick aluminum sheet
Application: panel ceiling

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.70

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.400.700.650.750.750.90

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Method (354): Measured

Terms of use