MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 214

Value from the PTB table, not verified

Nagelsturz + Eichler NE-Standard panel ceiling Type 110/15

NE-Standard panel ceiling – Type 110/15

PTB reference data

Original description

Nagelsturz + Eichler NE-Standard panel ceiling Type 110/15

Material properties

Manufacturer: Nagelsturz + Eichler GmbH & Co KG
Thickness: 20.5 mm
Perforation: 18%
Hole size: 2 mm
Backing: 20 mm mineral fiber backing
Surface: 0.5 mm thick aluminum sheet
Application: panel ceiling

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.75

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.400.700.650.750.750.90

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Nagelsturz + Eichler NE-Standard panel ceiling Type 110/15: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
20,5 mm · 92,5 kg / m³ · gelocht0.750.240.400.500.600.740.700.650.600.650.730.790.780.770.750.800.830.900.97
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: