MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Perforated metal ceiling panel backed with fiberglass

IAC Mark III

PTB reference data

Original description

Perforated metal ceiling panel backed with fiberglass

Material properties

Manufacturer: Industrial Acoustics Company
Thickness: 2 inches, 3 inches
Wall distance: 400 mm
Backing: fiberglass
Application: ceiling

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 2 variants

αw
1.00

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.650.701.001.001.001.00

Create a permanent free account — Access frequency bands, variants and export.

Free. No password required.

CompareValue
2 inches1.8 lb/ft²αw1.00
3 inches3.1 lb/ft²αw0.95

Dimensions: 24 x 48 inches

Distance: 400 mm

Terms of use
Measured values as a table (2 measurements)
Perforated metal ceiling panel backed with fiberglass: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
2 inches · 1.8 lb/ft² · 400 mm1.000.630.710.981.111.031.08
3 inches · 3.1 lb/ft² · 400 mm0.950.560.841.161.160.920.82
Measured values as a table (2 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated:

Calculate reverberation time with this product