Mineral woolHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Manufacturer data

Value from the PTB table, not verified

Ecophon Hygiene Protec Baffle, glass wool fiber absorber

Ecophon – Hygiene Protec Baffle center distance 600

PTB reference data

Original description

Ecophon Hygiene Protec Baffle, glass wool fiber absorber

Material properties

Manufacturer: Ecophon GmbH
Thickness: 50 mm
Wall distance: 800 mm
Surface: reinforced color coating Akutex T
Application: baffle
Mounting: sub-frame made of painted galvanized steel

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.70

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.400.400.750.900.850.80

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Ecophon Hygiene Protec Baffle, glass wool fiber absorber: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw63 Hz125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
50 mm · ca.3 kg pro baffle · tKh = 800 mm (totale Konstruktionshöhe) · Für Bereiche with relativ geringer Verschmutzung, überall dort, wo sämtliche Flächen des Absorbers gereinigt werden müssen, kann beidseitig feucht gereinigt werden · Akutex T verstärkt0.700.150.400.400.750.900.850.80
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated:

See also