FabricHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Armstrong Type 3301 cloth-faced fiberglass lay-in panel, painted

Type 3301

PTB reference data

Original description

Armstrong Type 3301 cloth-faced fiberglass lay-in panel, painted

Material properties

Manufacturer: Armstrong World Industries
Thickness: 3/4 inch
Wall distance: 400 mm
Surface: painted

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 2 variants

αw
0.70

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.700.850.600.850.951.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
0.35 lb/ft²αw0.70
0.4 lb/ft²αw0.65

Dimensions: 24 x 48 inches

Distance: 400 mm

Terms of use
Measured values as a table (2 measurements)
Armstrong Type 3301 cloth-faced fiberglass lay-in panel, painted: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
3/4 inches · 0.4 lb/ft² · 400 mm0.650.480.350.710.961.051.04
3/4 inches · 0.35 lb/ft² · 400 mm0.700.710.870.620.860.961.07
Measured values as a table (2 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated:

See also