Mineral woolHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Fiberglass lay-in panel with microperforated vinyl facing

Type 2942

PTB reference data

Original description

Fiberglass lay-in panel with microperforated vinyl facing

Material properties

Manufacturer: Armstrong World Industries
Thickness: 1 1/2 inch
Wall distance: 400 mm
Backing: Fiberglass
Surface: microperforated vinyl facing

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
1.00

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.600.850.901.001.000.95

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Fiberglass lay-in panel with microperforated vinyl facing: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
1 1/2 inch · 0.3 lb/ft² · 400 mm1.000.620.830.901.101.060.94
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: