WoodBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 156

Value from the PTB table, not verified

Wilhelmi acoustic panel Variantex 09 panel absorber

Wilhelmi acoustic panel – Variantex 09 (1981)

PTB reference data

Original description

Wilhelmi acoustic panel Variantex 09 panel absorber

Material properties

Manufacturer: Wilhelmi Werke AG
Thickness: approx. 18 mm
Wall distance: 50 mm, 300 mm
Surface: closed, resin-bonded foil, matte dabbed lacquer coating

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 2 variants

αw
0.15

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.450.200.150.100.100.10

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
300 mmαw0.15
50 mmαw0.10

Weight / density: 6 - 7,5 kg / m²

Terms of use
Measured values as a table (2 measurements)
Wilhelmi acoustic panel Variantex 09 panel absorber: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz
ca. 18 mm · 6 - 7,5 kg / m² · 50 mm0.100.260.320.390.470.310.220.220.160.130.110.100.090.080.070.070.070.10
ca. 18 mm · 6 - 7,5 kg / m² · 300 mm0.150.580.410.300.200.160.170.160.140.130.120.120.120.110.110.110.100.09
Measured values as a table (2 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated: