WoodHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994
Value from the PTB table, not verified
1 inch Tectum over 1 inch layer of 3 pcf fiberglass
panel
PTB reference data
Original description
1 inch Tectum over 1 inch layer of 3 pcf fiberglass
Material properties
Manufacturer: Tectum
Thickness: 2 inch
Wall distance: 40 mm
Backing: 1 inch 3 pcf fiberglass
Surface: perforated facing
Measurement data
Sound absorption
ISO 354 – reverberation chamber
αw
0.75
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.15 | 0.45 | 1.00 | 1.00 | 0.80 | 1.00 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
Measured values as a table (1 measurement)
| Build-up | αw | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| 2 inch · 1.9 lb/ft² · covered with perforated facing, airspace 40 mm | 0.75 | 0.16 | 0.43 | 1.00 | 1.05 | 0.79 | 0.98 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: