WoodLow-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Sound System Engineering, Don Davis and Carolyn Davis

Value from the PTB table, not verified

Plywood panel, 1/4 inch, mounted over 3 inch air space, with 1 inch glassfiber batts right behind the panel

PTB reference data

Original description

Plywood panel, 1/4 inch, mounted over 3 inch air space, with 1 inch glassfiber batts right behind the panel

Material properties

Thickness: 1/4 inch
Wall distance: 3 inch
Backing: 1 inch glassfiber batts

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.10

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.600.300.100.100.100.10

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Plywood panel, 1/4 inch, mounted over 3 inch air space, with 1 inch glassfiber batts right behind the panel: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
Measurement 10.100.600.300.100.090.090.09
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account