Reference surfaceLow-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: RAMSETE

Value from the PTB table, not verified

Ventilation pipes

PTB reference data

Original description

Ventilation pipes

Material properties

No further information available.

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.15

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.300.200.150.100.150.10

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Ventilation pipes: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw63 Hz125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz8000 Hz
Measurement 10.150.300.300.200.150.100.150.100.10
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: