Plaster & sprayHigh-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Manufacturer data unter http://asonad.de, Feb. 2001

Value from the PTB table, not verified

ICC Sonaspray K-13 FC cellulose-based acoustic spray plaster

Sonaspray K-13 FC

PTB reference data

Original description

ICC Sonaspray K-13 FC cellulose-based acoustic spray plaster

Material properties

Manufacturer: ICC
Thickness: 16 mm, 19 mm, 25 mm
Application: ceiling, wall
Mounting: spray application

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 3 variants

αw
0.70

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.200.400.901.001.001.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
25αw0.70
19αw0.55
16αw0.50

Application: Aufspritzen on Untergrund

Terms of use
Measured values as a table (3 measurements)
ICC Sonaspray K-13 FC cellulose-based acoustic spray plaster: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
16 · Aufspritzen on Untergrund · fein0.500.160.220.570.961.091.12
19 · Aufspritzen on Untergrund · fein0.550.180.270.671.021.111.12
25 · Aufspritzen on Untergrund · fein0.700.220.380.881.161.151.12
Measured values as a table (3 measurements)

Access frequency bands, variants and export. Create a permanent free account