MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Perforated steel panel backed by 4 inch layer of 3 1/2 pcf USG Thermafiber in Mylar

PTB reference data

Original description

Perforated steel panel backed by 4 inch layer of 3 1/2 pcf USG Thermafiber in Mylar

Material properties

Manufacturer: Commercial Acoustics
Thickness: 4 1/4 inch
Wall distance: 0 mm

Measurement data

Sound absorption

ISO 354 – reverberation chamber

αw
0.50

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.500.350.650.600.550.30

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

Terms of use
Measured values as a table (1 measurement)
Perforated steel panel backed by 4 inch layer of 3 1/2 pcf USG Thermafiber in Mylar: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαw125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
4 1/4 inch · 5 lb/ft² · 00.500.520.370.640.600.560.29
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: