Manufacturer

Lindner Group

Lindner Group, Arnstorf: metal ceilings, heating and cooling ceilings, raised floors, wall and ceiling linings and the MUTE+ sound absorber line.

All products by this manufacturerManufacturer website

Documents

Plafotherm GK HEKDA

Description

Plasterboard heating and cooling ceiling with a heat conducting profile as a fine grid. The perforation pattern and the centre spacing of the heat conducting profile determine the absorption. Nominal cooling capacity 81.70 to 99.60 W/m² at 10 K per EN 14240, nominal heating capacity 102 to 108 W/m² at 15 K per EN 14037:2003, depending on the board type and edge configuration and referred to the active area.

Technical data

Material: Plasterboard, highly compressed or with a graphite content
Surface: seamless, smooth or perforated
Up to fire class: A2-s1,d0

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 8 variants

αw
0.45

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.550.600.550.450.400.55

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
12-25 Qαw0.45
8/18 Qαw0.45
8-18 Rαw0.40
12-25 Rαw0.40
8-18 Qαw0.35
12-25 Rαw0.30
12-25 Qαw0.30
8-18 Rαw0.25

Absorber class: D

Test report: H180228/A_rev00 (Messung H180228/A7a_rev00)

Measurement date: 2018-03-06

Distance: 200 mm

Terms of use
Measured values as a table (8 measurements)
Plafotherm GK HEKDA: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαwAbsorber class100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
8-18 R · 200 mm · axis spacing 260 mm, with heat-conducting profile0.25E0.250.190.310.280.210.250.220.230.190.190.200.200.190.230.280.340.510.82
12-25 R · 200 mm · axis spacing 260 mm, with heat-conducting profile0.30D0.420.430.460.390.400.410.320.350.290.270.240.250.230.230.280.360.560.81
8-18 R · 200 mm · axis spacing 333 mm, with heat-conducting profile0.40D0.340.260.450.440.380.420.390.370.370.340.340.350.350.360.390.450.570.79
12-25 Q · 200 mm · axis spacing 260 mm, with heat-conducting profile0.30D0.380.510.450.360.380.390.330.320.290.270.250.250.250.240.290.360.540.77
8-18 Q · 200 mm · axis spacing 260 mm, with heat-conducting profile0.35D0.410.500.500.400.400.410.330.350.300.290.280.270.270.290.340.440.600.90
12-25 Q · 200 mm · axis spacing 333 mm, with heat-conducting profile0.45D0.520.550.560.550.560.650.630.580.500.450.410.430.420.370.390.410.500.71
12-25 R · 200 mm · axis spacing 333 mm, with heat-conducting profile0.40D0.520.500.570.540.500.580.540.530.450.410.380.410.370.350.380.440.560.76
8/18 Q · 200 mm · fine-grid heat-conducting profile, axis spacing 333 mm0.45D0.500.530.540.520.520.610.580.540.460.430.400.420.400.370.390.430.540.74