Manufacturer
Lindner Group
Lindner Group, Arnstorf: metal ceilings, heating and cooling ceilings, raised floors, wall and ceiling linings and the MUTE+ sound absorber line.
Plafotherm DS heating and cooling ceiling raft
Description
Freely suspended heating and cooling ceiling raft of perforated metal with acoustic fleece and an optional acoustic insert. Nominal cooling capacity 135 to 139 W/m² at 10 K per EN 14240, nominal heating capacity 163 to 167 W/m² at 15 K per EN 14037:2003, depending on the register and referred to the active area. Recycled content 45.8 per cent (DS 320).
Technical data
Measurement data
Sound absorption
ISO 354 – reverberation chamber· 24 variants
Frequency values
αp per ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.20 | 0.60 | 0.75 | 0.60 | 0.50 | 0.40 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
| Compare | Value | ||
|---|---|---|---|
| BASICline Rg 2,5-16 | 250 mm | αw0.55 | |
| Rg 1,8 - 19 | 250 mm | Aobj4.80m² | |
| BASICline Rg 2,5-16 | 250 mm | Aobj3.60m² | |
| BASICline Rg 2,5-16, smooth edge | 250 mm | Aobj3.30m² | |
| Rg 2,5 - 16 | 400 mm | Aobj2.70m² | |
| Rv 2,0 - 20 | 200 mm | Aobj2.30m² | |
| Rg 0,8 - 5 | 200 mm | Aobj2.00m² | |
| BASICline Rg 2,5-16 | 250 mm | Aobj1.90m² | |
| Rg 0,8 - 5 Crystal | 200 mm | Aobj1.70m² | |
| Rg 0,8 - 5 Pixel | 200 mm | Aobj1.70m² | |
| Rg 0,8 - 5 Paper | 200 mm | Aobj1.60m² | |
| Rg 0,8 - 5 | 200 mm | Aobj1.50m² | |
| Rg 0,8 - 5 Crystal | 200 mm | Aobj1.40m² | |
| Rg 3,0 - 20 | 200 mm | Aobj1.30m² | |
| Rg 0,8 - 5 Paper | 200 mm | Aobj1.30m² | |
| Rg 0,8 - 5 Pixel | 200 mm | Aobj1.30m² | |
| REGULARline Rg 0,8-5 | 200 mm | Aobj1.20m² | |
| Rv 2,0 - 20 | 200 mm | Aobj1.10m² | |
| Rg 3,0 - 20 | 200 mm | Aobj1.10m² | |
| Rg 3,0 - 20 | 200 mm | Aobj0.90m² | |
| REGULARline Rg 0,8-5 | 200 mm | Aobj0.90m² | |
| Rg 0,8 - 5 Paper | 200 mm | Aobj0.60m² | |
| Rg 0,8 - 5 Crystal | 200 mm | Aobj0.60m² | |
| Rg 0,8 - 5 Pixel | 200 mm | Aobj0.60m² |
Absorber class: D
Test report: H230911M1/1a
Measurement date: 2023-09-11
Measured values as a table (24 measurements)
| Build-up | αw | Absorber class | 100 Hz | 125 Hz | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz | 5000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rv 2,0 - 20 · 200 mm · ceiling raft 1725 x 1390 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.30 | 0.70 | 1.00 | 1.40 | 1.70 | 1.80 | 1.80 | 1.70 | 1.30 | 1.10 | 1.30 | 1.20 | 1.10 | 1.20 | 1.10 | 1.10 | 1.00 |
| Rv 2,0 - 20 · 200 mm · ceiling raft 1725 x 1390 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.50 | 0.70 | 1.30 | 1.80 | 2.20 | 2.50 | 2.60 | 2.60 | 2.50 | 2.30 | 2.30 | 2.30 | 2.20 | 1.90 | 1.80 | 1.60 | 1.50 | 1.50 |
| Rg 1,8 - 19 · 250 mm · ceiling raft 4950 x 900 mm, with heat-conducting profile (Aobj, m²) | – | – | 1.90 | 3.10 | 3.10 | 3.50 | 4.30 | 5.40 | 5.20 | 4.80 | 4.10 | 4.20 | 4.80 | 4.50 | 4.30 | 4.00 | 3.70 | 3.50 | 3.10 | 3.00 |
| Rg 0,8 - 5 · 200 mm · ceiling raft 2400 x 1200 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.50 | 0.70 | 1.10 | 1.60 | 2.10 | 2.30 | 2.30 | 2.20 | 2.10 | 2.00 | 2.00 | 1.90 | 1.80 | 1.80 | 1.70 | 1.80 | 1.90 | 2.10 |
| Rg 0,8 - 5 · 200 mm · ceiling raft 2400 x 1200 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.40 | 0.90 | 1.40 | 1.40 | 1.90 | 2.10 | 2.00 | 2.00 | 1.80 | 1.70 | 1.50 | 1.50 | 1.40 | 1.20 | 1.20 | 1.20 | 1.30 | 1.60 |
| Rg 3,0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.50 | 0.80 | 0.80 | 1.10 | 1.40 | 1.50 | 1.50 | 1.50 | 1.30 | 1.30 | 1.40 | 1.30 | 1.30 | 1.20 | 1.10 | 1.10 | 1.10 |
| Rg 3,0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.40 | 0.60 | 0.60 | 0.90 | 1.20 | 1.20 | 1.20 | 1.30 | 1.10 | 1.10 | 1.20 | 1.10 | 1.10 | 1.00 | 1.00 | 1.00 | 0.90 |
| Rg 3,0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.30 | 0.60 | 0.60 | 0.80 | 1.10 | 1.10 | 1.10 | 1.20 | 1.00 | 0.90 | 1.00 | 1.00 | 0.90 | 0.80 | 0.90 | 0.80 | 0.70 |
| Rg 2,5 - 16 · 400 mm · ceiling raft 3500 x 900 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.60 | 1.90 | 2.80 | 2.50 | 2.90 | 2.80 | 2.60 | 2.40 | 2.80 | 2.60 | 2.70 | 2.80 | 2.70 | 2.50 | 2.30 | 2.20 | 1.90 | 1.80 |
| Rg 0,8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.60 | 1.30 | 1.70 | 1.60 | 1.80 | 1.80 | 1.70 | 1.60 | 1.50 | 1.60 | 1.60 | 1.50 | 1.50 | 1.40 | 1.30 | 1.30 | 1.30 |
| Rg 0,8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.20 | 0.80 | 0.90 | 0.90 | 0.90 | 0.90 | 0.80 | 0.70 | 0.60 | 0.60 | 0.70 | 0.70 | 0.70 | 0.70 | 0.60 | 0.60 | 0.70 |
| Rg 0,8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.20 | 1.20 | 1.40 | 1.60 | 1.40 | 1.40 | 1.20 | 1.30 | 1.30 | 1.30 | 1.40 | 1.30 | 1.30 | 1.20 | 1.40 |
| Rg 0,8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.70 | 1.30 | 1.60 | 1.60 | 1.80 | 1.80 | 1.80 | 1.70 | 1.60 | 1.70 | 1.80 | 1.70 | 1.70 | 1.70 | 1.60 | 1.50 | 1.60 |
| Rg 0,8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.30 | 0.90 | 0.90 | 0.80 | 0.90 | 0.80 | 0.70 | 0.70 | 0.60 | 0.60 | 0.70 | 0.70 | 0.80 | 0.80 | 0.80 | 0.80 | 1.00 |
| Rg 0,8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.20 | 1.20 | 1.40 | 1.50 | 1.50 | 1.40 | 1.30 | 1.40 | 1.50 | 1.50 | 1.60 | 1.50 | 1.50 | 1.40 | 1.60 |
| Rg 0,8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.60 | 1.20 | 1.50 | 1.50 | 1.60 | 1.80 | 1.70 | 1.70 | 1.50 | 1.70 | 1.60 | 1.60 | 1.60 | 1.60 | 1.50 | 1.40 | 1.50 |
| Rg 0,8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.20 | 0.70 | 0.80 | 0.70 | 0.90 | 0.90 | 0.80 | 0.70 | 0.50 | 0.60 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 0.90 |
| Rg 0,8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.10 | 1.20 | 1.40 | 1.60 | 1.40 | 1.30 | 1.30 | 1.30 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 |
| REGULARline Rg 0,8-5 · 200 mm · ceiling raft 1070 x 1070 mm, 3 units (Aobj, m²) | – | – | 0.10 | 0.20 | 0.70 | 0.70 | 0.80 | 0.90 | 1.00 | 0.90 | 0.90 | 0.80 | 0.90 | 0.90 | 0.90 | 0.80 | 0.70 | 0.70 | 0.60 | 0.70 |
| REGULARline Rg 0,8-5 · 200 mm · ceiling raft 1070 x 1070 mm, 3 units (Aobj, m²) | – | – | 0.10 | 0.30 | 0.80 | 0.90 | 1.00 | 0.90 | 1.10 | 1.10 | 1.10 | 1.10 | 1.20 | 1.10 | 1.00 | 1.00 | 0.90 | 1.00 | 0.90 | 1.00 |
| BASICline Rg 2,5-16 · 250 mm · ceiling raft 900 x 4000 mm (Aobj, m²) | – | – | 0.50 | 1.40 | 2.00 | 2.60 | 2.90 | 3.20 | 3.50 | 3.40 | 3.20 | 3.20 | 3.60 | 3.50 | 3.70 | 3.40 | 3.40 | 3.30 | 3.00 | 2.90 |
| BASICline Rg 2,5-16 · 250 mm · ceiling raft 900 x 2000 mm, 2 units (Aobj, m²) | – | – | 0.30 | 0.70 | 1.10 | 1.30 | 1.60 | 1.80 | 1.70 | 1.70 | 1.70 | 1.70 | 1.90 | 1.90 | 1.90 | 1.80 | 1.80 | 1.60 | 1.60 | 1.60 |