Plafotherm DS heating and cooling ceiling raft
Manufacturer
Lindner Group
Lindner Group, Arnstorf: metal ceilings, heating and cooling ceilings, raised floors, wall and ceiling linings and the MUTE+ sound absorber line.
Description
Freely suspended heating and cooling ceiling raft of perforated metal with acoustic fleece and an optional acoustic insert. Nominal cooling capacity 135 to 139 W/m² at 10 K per EN 14240, nominal heating capacity 163 to 167 W/m² at 15 K per EN 14037:2003, depending on the register and referred to the active area. Recycled content 45.8 per cent (DS 320).
Technical data
Measurement data
Sound absorption
ISO 354 – reverberation chamber· 24 variants
Frequency values
Create a permanent free account. Access frequency bands, variants and export.
Free. No password required.
| Compare | Value | ||||
|---|---|---|---|---|---|
| BASICline Rg 2.5-16 | 250 mm | ceiling raft 900 x 4000 mm | — | αw0.55 | |
| Rg 1.8 - 19 | 250 mm | ceiling raft 4950 x 900 mm, with heat-conducting profile | 20 mm | Aobj4.80m² | |
| BASICline Rg 2.5-16 | 250 mm | ceiling raft 900 x 4000 mm | 40 mm all around | Aobj3.60m² | |
| BASICline Rg 2.5-16, smooth edge | 250 mm | ceiling raft 900 x 4000 mm | 40 mm on the long side | Aobj3.30m² | |
| Rg 2.5 - 16 | 400 mm | ceiling raft 3500 x 900 mm, acoustic heat-conducting profile | — | Aobj2.70m² | |
| Rv 2.0 - 20 | 200 mm | ceiling raft 1725 x 1390 mm, with heat-conducting profile | 20 mm | Aobj2.30m² | |
| Rg 0.8 - 5 | 200 mm | ceiling raft 2400 x 1200 mm, with heat-conducting profile | 20 mm (20 % coverage) | Aobj2.00m² | |
| BASICline Rg 2.5-16 | 250 mm | ceiling raft 900 x 2000 mm, 2 units | 40 mm all around | Aobj1.90m² | |
| Rg 0.8 - 5 Crystal | 200 mm | ceiling raft 2045 x 1030 mm, with heat-conducting profile | 30 mm | Aobj1.70m² | |
| Rg 0.8 - 5 Pixel | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | 30 mm | Aobj1.70m² | |
| Rg 0.8 - 5 Paper | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | 30 mm | Aobj1.60m² | |
| Rg 0.8 - 5 | 200 mm | ceiling raft 2400 x 1200 mm, with heat-conducting profile | — | Aobj1.50m² | |
| Rg 0.8 - 5 Crystal | 200 mm | ceiling raft 2045 x 1030 mm, with heat-conducting profile | 30 mm (50 % coverage) | Aobj1.40m² | |
| Rg 3.0 - 20 | 200 mm | ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile | 20 mm | Aobj1.30m² | |
| Rg 0.8 - 5 Paper | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | 30 mm (50 % coverage) | Aobj1.30m² | |
| Rg 0.8 - 5 Pixel | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | 30 mm (50 % coverage) | Aobj1.30m² | |
| REGULARline Rg 0.8-5 | 200 mm | ceiling raft 1070 x 1070 mm, 3 units | 40 mm all around | Aobj1.20m² | |
| Rv 2.0 - 20 | 200 mm | ceiling raft 1725 x 1390 mm, with heat-conducting profile | — | Aobj1.10m² | |
| Rg 3.0 - 20 | 200 mm | ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile | 20 mm (30 % coverage) | Aobj1.10m² | |
| Rg 3.0 - 20 | 200 mm | ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile | — | Aobj0.90m² | |
| REGULARline Rg 0.8-5 | 200 mm | ceiling raft 1070 x 1070 mm, 3 units | 40 mm on the long side | Aobj0.90m² | |
| Rg 0.8 - 5 Paper | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | — | Aobj0.60m² | |
| Rg 0.8 - 5 Crystal | 200 mm | ceiling raft 2045 x 1030 mm, with heat-conducting profile | — | Aobj0.60m² | |
| Rg 0.8 - 5 Pixel | 200 mm | ceiling raft 2000 x 1000 mm, with heat-conducting profile | — | Aobj0.60m² |
Absorber class: D
Test report: H230911M1/1a
Measurement date: 11/09/2023
Test setup: ceiling raft 900 x 4000 mm
Measured values as a table (24 measurements)
| Build-up | αw | Absorber class | 100 Hz | 125 Hz | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz | 5000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Rv 2.0 - 20 · 200 mm · ceiling raft 1725 x 1390 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.30 | 0.70 | 1.00 | 1.40 | 1.70 | 1.80 | 1.80 | 1.70 | 1.30 | 1.10 | 1.30 | 1.20 | 1.10 | 1.20 | 1.10 | 1.10 | 1.00 |
| Rv 2.0 - 20 · 200 mm · ceiling raft 1725 x 1390 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.50 | 0.70 | 1.30 | 1.80 | 2.20 | 2.50 | 2.60 | 2.60 | 2.50 | 2.30 | 2.30 | 2.30 | 2.20 | 1.90 | 1.80 | 1.60 | 1.50 | 1.50 |
| Rg 1.8 - 19 · 250 mm · ceiling raft 4950 x 900 mm, with heat-conducting profile (Aobj, m²) | – | – | 1.90 | 3.10 | 3.10 | 3.50 | 4.30 | 5.40 | 5.20 | 4.80 | 4.10 | 4.20 | 4.80 | 4.50 | 4.30 | 4.00 | 3.70 | 3.50 | 3.10 | 3.00 |
| Rg 0.8 - 5 · 200 mm · ceiling raft 2400 x 1200 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.50 | 0.70 | 1.10 | 1.60 | 2.10 | 2.30 | 2.30 | 2.20 | 2.10 | 2.00 | 2.00 | 1.90 | 1.80 | 1.80 | 1.70 | 1.80 | 1.90 | 2.10 |
| Rg 0.8 - 5 · 200 mm · ceiling raft 2400 x 1200 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.40 | 0.90 | 1.40 | 1.40 | 1.90 | 2.10 | 2.00 | 2.00 | 1.80 | 1.70 | 1.50 | 1.50 | 1.40 | 1.20 | 1.20 | 1.20 | 1.30 | 1.60 |
| Rg 3.0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.50 | 0.80 | 0.80 | 1.10 | 1.40 | 1.50 | 1.50 | 1.50 | 1.30 | 1.30 | 1.40 | 1.30 | 1.30 | 1.20 | 1.10 | 1.10 | 1.10 |
| Rg 3.0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.40 | 0.60 | 0.60 | 0.90 | 1.20 | 1.20 | 1.20 | 1.30 | 1.10 | 1.10 | 1.20 | 1.10 | 1.10 | 1.00 | 1.00 | 1.00 | 0.90 |
| Rg 3.0 - 20 · 200 mm · ceiling raft 1100 x 1000 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.30 | 0.60 | 0.60 | 0.80 | 1.10 | 1.10 | 1.10 | 1.20 | 1.00 | 0.90 | 1.00 | 1.00 | 0.90 | 0.80 | 0.90 | 0.80 | 0.70 |
| Rg 2.5 - 16 · 400 mm · ceiling raft 3500 x 900 mm, acoustic heat-conducting profile (Aobj, m²) | – | – | 0.60 | 1.90 | 2.80 | 2.50 | 2.90 | 2.80 | 2.60 | 2.40 | 2.80 | 2.60 | 2.70 | 2.80 | 2.70 | 2.50 | 2.30 | 2.20 | 1.90 | 1.80 |
| Rg 0.8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.60 | 1.30 | 1.70 | 1.60 | 1.80 | 1.80 | 1.70 | 1.60 | 1.50 | 1.60 | 1.60 | 1.50 | 1.50 | 1.40 | 1.30 | 1.30 | 1.30 |
| Rg 0.8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.20 | 0.80 | 0.90 | 0.90 | 0.90 | 0.90 | 0.80 | 0.70 | 0.60 | 0.60 | 0.70 | 0.70 | 0.70 | 0.70 | 0.60 | 0.60 | 0.70 |
| Rg 0.8 - 5 Paper · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.20 | 1.20 | 1.40 | 1.60 | 1.40 | 1.40 | 1.20 | 1.30 | 1.30 | 1.30 | 1.40 | 1.30 | 1.30 | 1.20 | 1.40 |
| Rg 0.8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.30 | 0.70 | 1.30 | 1.60 | 1.60 | 1.80 | 1.80 | 1.80 | 1.70 | 1.60 | 1.70 | 1.80 | 1.70 | 1.70 | 1.70 | 1.60 | 1.50 | 1.60 |
| Rg 0.8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.30 | 0.90 | 0.90 | 0.80 | 0.90 | 0.80 | 0.70 | 0.70 | 0.60 | 0.60 | 0.70 | 0.70 | 0.80 | 0.80 | 0.80 | 0.80 | 1.00 |
| Rg 0.8 - 5 Crystal · 200 mm · ceiling raft 2045 x 1030 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.20 | 1.20 | 1.40 | 1.50 | 1.50 | 1.40 | 1.30 | 1.40 | 1.50 | 1.50 | 1.60 | 1.50 | 1.50 | 1.40 | 1.60 |
| Rg 0.8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.60 | 1.20 | 1.50 | 1.50 | 1.60 | 1.80 | 1.70 | 1.70 | 1.50 | 1.70 | 1.60 | 1.60 | 1.60 | 1.60 | 1.50 | 1.40 | 1.50 |
| Rg 0.8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.10 | 0.20 | 0.70 | 0.80 | 0.70 | 0.90 | 0.90 | 0.80 | 0.70 | 0.50 | 0.60 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 0.90 |
| Rg 0.8 - 5 Pixel · 200 mm · ceiling raft 2000 x 1000 mm, with heat-conducting profile (Aobj, m²) | – | – | 0.20 | 0.50 | 1.10 | 1.10 | 1.20 | 1.40 | 1.60 | 1.40 | 1.30 | 1.30 | 1.30 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 | 1.40 |
| REGULARline Rg 0.8-5 · 200 mm · ceiling raft 1070 x 1070 mm, 3 units (Aobj, m²) | – | – | 0.10 | 0.20 | 0.70 | 0.70 | 0.80 | 0.90 | 1.00 | 0.90 | 0.90 | 0.80 | 0.90 | 0.90 | 0.90 | 0.80 | 0.70 | 0.70 | 0.60 | 0.70 |
| REGULARline Rg 0.8-5 · 200 mm · ceiling raft 1070 x 1070 mm, 3 units (Aobj, m²) | – | – | 0.10 | 0.30 | 0.80 | 0.90 | 1.00 | 0.90 | 1.10 | 1.10 | 1.10 | 1.10 | 1.20 | 1.10 | 1.00 | 1.00 | 0.90 | 1.00 | 0.90 | 1.00 |
| BASICline Rg 2.5-16 · 250 mm · ceiling raft 900 x 4000 mm (Aobj, m²) | – | – | 0.50 | 1.40 | 2.00 | 2.60 | 2.90 | 3.20 | 3.50 | 3.40 | 3.20 | 3.20 | 3.60 | 3.50 | 3.70 | 3.40 | 3.40 | 3.30 | 3.00 | 2.90 |
| BASICline Rg 2.5-16 · 250 mm · ceiling raft 900 x 2000 mm, 2 units (Aobj, m²) | – | – | 0.30 | 0.70 | 1.10 | 1.30 | 1.60 | 1.80 | 1.70 | 1.70 | 1.70 | 1.70 | 1.90 | 1.90 | 1.90 | 1.80 | 1.80 | 1.60 | 1.60 | 1.60 |
| BASICline Rg 2.5-16, smooth edge · 250 mm · ceiling raft 900 x 4000 mm (Aobj, m²) | – | – | 0.50 | 1.30 | 1.90 | 2.60 | 2.80 | 3.20 | 3.30 | 3.40 | 3.20 | 3.00 | 3.30 | 3.30 | 3.20 | 2.90 | 2.60 | 2.30 | 2.10 | 1.70 |
| BASICline Rg 2.5-16 · 250 mm · ceiling raft 900 x 4000 mm | 0.55 | D | 0.07 | 0.18 | 0.42 | 0.51 | 0.58 | 0.67 | 0.82 | 0.77 | 0.69 | 0.58 | 0.66 | 0.59 | 0.57 | 0.50 | 0.46 | 0.43 | 0.40 | 0.37 |
Measured values as a table (24 measurements)
Access frequency bands, variants and export. Create a permanent free account