Manufacturer

Lindner Group

Lindner Group, Arnstorf: metal ceilings, heating and cooling ceilings, raised floors, wall and ceiling linings and the MUTE+ sound absorber line.

All products by this manufacturerManufacturer website

Plafotherm B/E heating and cooling ceiling

EPD available

Description

Metal heating and cooling ceiling as a band raster ceiling or hook-in ceiling. The build-up combines a perforated ceiling panel, acoustic fleece and an optional acoustic insert with a register applied to the rear for heating and cooling. Nominal cooling capacity 102 to 112 W/m² at 10 K per EN 14240, nominal heating capacity 118 to 126 W/m² at 15 K per EN 14037:2003, depending on the register and referred to the active area. Recycled content 46.8 per cent.

Technical data

Material: Galvanised steel sheet
Surface: Powder coating COLOURline, MOODline deep matt, ARTline decor, GRAPHICline digital printing
Up to fire class: A2-s1,d0
Certifications: CE per EN 13964, EPD per EN 15804, FDES in the INIES database, TAIM technical manual for metal ceilings, VOC emission class A+, Indoor Air Comfort Gold

Measurement data

Sound absorption

ISO 354 – reverberation chamber· 15 variants

αw
0.75

Frequency values

αp per ISO 11654

f (Hz)1252505001k2k4k
αp0.600.750.850.750.750.65

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
Rv 3,0 - 20200 mmαw0.75
Rv 1,8 - 20200 mmαw0.70
Rv 1,8 - 20200 mmαw0.70
Rv 3,0 - 20200 mmαw0.70
Rd 3,0 - 30300 mmαw0.70
Rd 3,0 - 30300 mmαw0.60
Rv 1,8 - 20200 mmαw0.55
Rv 2,0 - 20200 mmαw0.55
Rg 0,8 - 5200 mmαw0.55
Rv 1,8 - 20200 mmαw0.55
Rv 2,0 - 20200 mmαw0.50
Rg 1,6 - 13200 mmαw0.50
Rg 0,8 - 5200 mmαw0.50
Rv 2,0 - 20200 mmαw0.45
Rv 1,8 - 20200 mmαw0.45

Absorber class: C

Terms of use
Measured values as a table (15 measurements)
Plafotherm B/E heating and cooling ceiling: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upαwAbsorber class100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
Rv 1,8 - 20 · 200 mm · with heat-conducting profile0.70C0.280.260.310.360.350.500.640.790.911.021.101.081.081.030.930.820.720.72
Rv 2,0 - 20 · 200 mm · with heat-conducting profile0.45D0.260.370.610.720.780.780.730.710.630.500.430.490.460.440.430.390.360.33
Rv 2,0 - 20 · 200 mm · with heat-conducting profile0.50D0.180.280.330.340.480.620.690.760.770.750.710.650.580.520.470.400.340.33
Rv 1,8 - 20 · 200 mm · heat-conducting profile 80 mm0.70C0.260.270.330.400.460.610.720.800.850.930.900.850.780.740.650.580.540.60
Rv 1,8 - 20 · 200 mm · heat-conducting profile 80 mm0.55D0.240.230.250.270.250.330.410.530.610.760.790.850.860.800.750.640.570.47
Rg 1,6 - 13 · 200 mm · with heat-conducting profile0.50D0.220.280.330.410.600.760.820.870.840.790.740.650.590.500.460.400.360.35
Rv 3,0 - 20 · 200 mm · acoustic heat-conducting profile0.70C0.470.540.630.560.760.780.850.850.880.720.680.730.720.690.630.640.620.53
Rv 3,0 - 20 · 200 mm · acoustic heat-conducting profile0.75C0.520.600.660.600.800.810.860.870.880.750.750.800.770.750.690.690.660.59
Rv 2,0 - 20 · 200 mm · 20 mm0.55D0.370.570.850.880.810.880.840.790.700.600.620.600.540.510.460.410.390.37
Rg 0,8 - 5 · 200 mm · with heat-conducting profile0.50D0.520.570.600.610.640.660.700.720.670.590.540.570.520.450.420.380.330.32
Rg 0,8 - 5 · 200 mm · with heat-conducting profile0.55D0.630.600.670.620.610.650.670.660.620.590.580.610.520.480.430.410.380.37
Rd 3,0 - 30 · 300 mm · with heat-conducting profile0.60C0.310.490.760.760.730.760.810.680.610.680.640.600.570.540.520.480.450.40
Rd 3,0 - 30 · 300 mm · with heat-conducting profile0.70C0.310.510.740.730.730.760.810.690.660.750.730.740.710.660.640.610.570.58
Rv 1,8 - 20 · 200 mm · heat-conducting profile 120 mm0.45D0.510.620.660.600.800.840.770.720.610.480.440.450.430.410.400.380.330.31
Rv 1,8 - 20 · 200 mm · heat-conducting profile 120 mm0.55D0.570.610.640.590.770.750.660.660.600.510.530.560.520.470.440.410.390.43
Measured values as a table (15 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated: