WoodHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 155

Value from the PTB table, not verified

Wilhelmi Mikropor UB acoustic panel made of vermiculite

Wilhelmi-Akustikplatte – Mikropor UB (1981)

PTB reference data

Original description

Wilhelmi Mikropor UB acoustic panel made of vermiculite

Material properties

Manufacturer: Wilhelmi Werke AG
Thickness: approx. 0.6 in
Wall distance: 1.9 in
Surface: acoustic non-woven, fine-pored special coating
Up to fire class: non-combustible

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.55
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.450.700.500.450.55

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.55 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Wilhelmi Mikropor UB acoustic panel made of vermiculite: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
ca. 15 mm · ca. 4 kg / m² · 48 mm · acoustic fleece, feinporiger Speziallack0.550.030.090.130.230.500.600.700.740.700.590.540.430.460.480.480.530.550.530.55
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account