WoodHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 153

Value from the PTB table, not verified

Wilhelmi Mikropor ST wood wool acoustic panel

Wilhelmi-Akustikplatte – Mikropor ST (1981)

PTB reference data

Original description

Wilhelmi Mikropor ST wood wool acoustic panel

Material properties

Manufacturer: Wilhelmi Werke AG
Thickness: approx. 0.8 in
Wall distance: 1.9 in
Surface: Mikropor foil with lacquer coating

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.15
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.250.200.150.100.100.15

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.15 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Wilhelmi Mikropor ST wood wool acoustic panel: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
ca. 20 mm · 8 kg / m² · 48 mm · optisch wie Mikropor S0.150.180.280.300.230.220.180.150.140.090.110.090.100.100.120.140.140.140.140.17
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account