WoodHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: Dalenbäck, Datensatz der CATT-Software, November 2000. Ursprüngliche Quelle: Wilhelmi Lieferprogramm Akustikplatten 2.19/77, Ergänzung PTB. Data-Category in CATT: WILHELMI, C: Ceilings, D: Wilhelmi
Value from the PTB table, not verified
Wilhelmi-Mikropor-S acoustic panel for ceilings
PTB reference data
Original description
Wilhelmi-Mikropor-S acoustic panel for ceilings
Material properties
Wall distance: 12 in
Application: ceiling
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.55
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.40 | 0.30 | 0.50 | 0.80 | 0.60 | 0.60 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.55 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| Measurement 1 | 0.55 | 0.42 | 0.28 | 0.49 | 0.78 | 0.58 | 0.62 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: