Reference surfaceLow-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Dalenbäck, Datensatz der CATT-Software, November 2000. Data-Category in CATT: PLASTER6, C: Walls, D: 9

Value from the PTB table, not verified

Walls, 9 mm plaster on 25 mm studs (no mineral wool)

PTB reference data

Original description

Walls, 9 mm plaster on 25 mm studs (no mineral wool)

Material properties

Thickness: 0.4 in plaster, 1 in studs
Application: wall

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.10
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.150.150.100.050.050.05

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.10 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Walls, 9 mm plaster on 25 mm studs (no mineral wool): sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
Measurement 10.100.150.160.080.060.050.06
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account