Reference surfaceHigh-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: DNA-Tabelle 1968 a 6-3

Value from the PTB table, not verified

Carpet, flat, loop pile, 5.3 mm, 1.98 kg/m², 250 Rayl

PTB reference data

Original description

Carpet, flat, loop pile, 5.3 mm, 1.98 kg/m², 250 Rayl

Material properties

Thickness: 0.2 in
Surface weight: 1.98 kg/m²
Flow resistance: 250 Rayl
Mounting: flat

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.15
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.000.000.050.100.300.60

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.15 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Carpet, flat, loop pile, 5.3 mm, 1.98 kg/m², 250 Rayl: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
5,3 mm · 1,98 kg/m^2 · Schlingenwebart0.150.020.000.020.030.030.000.050.050.080.080.110.180.220.310.420.500.580.680.88
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: