Reference: audienceHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: JASA 104 (6) Dec 1998
Value from the PTB table, not verified
Heavily upholstered chair, occupied, seat back 7.5 cm, seat bottom 10 cm, arm rests 2 cm, Kanagawa (series 4)
PTB reference data
Original description
Heavily upholstered chair, occupied, seat back 7.5 cm, seat bottom 10 cm, arm rests 2 cm, Kanagawa (series 4)
Material properties
No further information available.
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
Values per m² of audience area, not per chair or person.
NRC
0.80
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.70 | 0.75 | 0.75 | 0.75 | 0.85 | 0.90 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.80 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| Measurement 1 | 0.80 | 0.68 | 0.74 | 0.77 | 0.77 | 0.84 | 0.89 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: