Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: JASA 104 (6) Dec 1998
Value from the PTB table, not verified
Specially upholstered chair, unoccupied, front side of seat back 65 %, 2 cm, rear side of seat back 0, top of seat bottom 4-6 cm, arm rests solid, upholstery cushion is covered with a vinyl sheet (series 2)
Original description
Specially upholstered chair, unoccupied, front side of seat back 65 %, 2 cm, rear side of seat back 0, top of seat bottom 4-6 cm, arm rests solid, upholstery cushion is covered with a vinyl sheet (series 2)
Material properties
No further information available.
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
Values per m² of audience area, not per chair or person.
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.40 | 0.35 | 0.40 | 0.35 | 0.35 | 0.25 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.35 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| Measurement 1 | 0.35 | 0.38 | 0.35 | 0.40 | 0.37 | 0.34 | 0.25 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: