WoodLow-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: DNA-Tabelle 1968, c1-19

Value from the PTB table, not verified

Plywood panel, 6 mm, with 50 mm mineral fiber backing

PTB reference data

Original description

Plywood panel, 6 mm, with 50 mm mineral fiber backing

Material properties

Thickness: 0.2 in
Wall distance: 3.9 in
Dimensions: 3180 × 125 in
Surface weight: 4.2 kg/m²
Backing: 2 in mineral fiber panels, 100 kg/m³
Flow resistance: 20 Rayl/cm
Mounting: 25/2 in battens

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.15
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.650.300.100.050.050.05

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.15 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Plywood panel, 6 mm, with 50 mm mineral fiber backing: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
6 mm · 100 mm0.150.580.750.580.400.300.220.150.120.080.080.050.050.050.040.050.040.030.070.03
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account