FeltHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Acoustical panels (Siegfried Keller Pyramid panel)

Pyramid panel

PTB reference data

Original description

Acoustical panels (Siegfried Keller Pyramid panel)

Material properties

Manufacturer: Siegfried Keller AG
Thickness: 2 in
Wall distance: 0 in

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.85
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.150.400.901.001.001.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.85 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Acoustical panels (Siegfried Keller Pyramid panel): sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
50 mm · 1.4 kg / m² · 00.850.150.400.901.001.101.10