Reference surfaceHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Carpet: Loop pile tufted carpet, 0.7 kg/m²: no pad

PTB reference data

Original description

Carpet: Loop pile tufted carpet, 0.7 kg/m²: no pad

Material properties

Surface weight: 0.7 kg/m²

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.30
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.050.100.150.350.600.75

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.30 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Carpet: Loop pile tufted carpet, 0.7 kg/m²: no pad: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
0.7 kg / m²0.300.040.080.170.330.590.75
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account