GypsumBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 237

Value from the PTB table, not verified

Rigips RL 15/30 perforated panel with fiber absorber

Rigips perforated panel – RL 15/30

PTB reference data

Original description

Rigips RL 15/30 perforated panel with fiber absorber

Material properties

Manufacturer: Rigips GmbH
Thickness: 0.4 in, 0.5 in
Wall distance: 3.9 in, 7.9 in, 16 in
Perforation: regular perforation
Hole size: 0.6 in
Backing: non-woven backing and mineral fiber panel backing

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 3 variants

NRC
0.80

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.750.900.700.800.700.65

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
16 inNRC0.80
3.9 inNRC0.80
7.9 inNRC0.80

NRC: 0.80 (derived from ISO 354 lab data)

Weight / density: 7,5 kg / m² (0.4 in) 10 kg / m² (0.5 in)

Dimensions: bis 3000x 49 in

Terms of use
Measured values as a table (3 measurements)
Rigips RL 15/30 perforated panel with fiber absorber: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
9,5 / 12,5 mm · 7,5 kg / m² (9,5mm) 10 kg / m² (12,5mm) · 100 mm0.800.200.290.390.630.670.951.011.010.990.860.820.700.640.660.650.600.630.570.63
9,5 / 12,5 mm · 7,5 kg / m² (9,5mm) 10 kg / m² (12,5mm) · 200 mm0.800.330.390.640.870.950.900.930.910.830.700.670.770.690.690.620.610.580.600.60
9,5 / 12,5 mm · 7,5 kg / m² (9,5mm) 10 kg / m² (12,5mm) · 400 mm0.800.630.750.860.920.960.800.630.690.830.820.790.780.730.700.670.630.630.620.63
Measured values as a table (3 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated: