MetalBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 227

Value from the PTB table, not verified

Richter System 16 aluminum panel ceiling with felt

Richter System 16

PTB reference data

Original description

Richter System 16 aluminum panel ceiling with felt

Material properties

Manufacturer: Rheinhold & Mahla AG
Wall distance: 5.9 in
Perforation: 11.15 %
Hole size: 0.1 in
Backing: 0.4 in Firet felt
Application: ceiling

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.45
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.200.500.600.550.60

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.45 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Richter System 16 aluminum panel ceiling with felt: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
0,6 kg / m² · 150 mm0.450.050.080.110.140.160.340.420.550.600.620.600.580.530.520.600.610.610.630.68