Reference surfaceHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: J.Meyer, Kirchenakustik, Verlag E.Bochinsky

Value from the PTB table, not verified

Plaster on masonry, porous

PTB reference data

Original description

Plaster on masonry, porous

Material properties

Surface: porous surface

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.10
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.050.050.050.100.100.10

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.10 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Plaster on masonry, porous: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
Measurement 10.100.050.050.070.090.100.12
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: