Reference: audienceHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Dalenbäck, Datensatz der CATT-Software, November 2000. Data-Category in CATT: AUDIENCE_072, C: Audiences, D: Audience

Value from the PTB table, not verified

Audiences, audience area, 0.72 persons/m²

PTB reference data

Original description

Audiences, audience area, 0.72 persons/m²

Material properties

Density: 0.72 persons/m²
Application: audience area

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

Values per m² of audience area, not per chair or person.

NRC
0.50
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.200.400.650.750.70

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.50 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Audiences, audience area, 0.72 persons/m²: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
0.72 persons / m20.500.100.210.410.650.750.71
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account