Stone & concreteHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Wärme Kälte Schall Heft 1 (March) 1970

Value from the PTB table, not verified

Polyklet acoustic perforated brick with Sillan panels

PTB reference data

Original description

Polyklet acoustic perforated brick with Sillan panels

Material properties

Wall distance: 2 in
Perforation: approx. 43%
Backing: 1.2 in Sillan acoustic panels

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.65
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.250.400.600.800.800.70

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.65 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Polyklet acoustic perforated brick with Sillan panels: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz
50 mm0.650.200.260.340.400.460.540.600.660.740.800.800.800.800.770.730.70
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: