Glass & transparentBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: IBP Mitteilung 258, Fraunhofer-Inst. F. Bauphysik, Stuttgart, 1994

Value from the PTB table, not verified

Micro-perforated acrylic glass sound absorber

PTB reference data

Original description

Micro-perforated acrylic glass sound absorber

Material properties

Thickness: 0.2 in
Wall distance: 3.9 in, 1 in, 2 in

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 4 variants

NRC
0.55

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.250.600.850.500.250.15

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
3.9 inNRC0.55
1 inNRC0.35
2 inNRC0.35
3.9 inNRC0.35

NRC: 0.55 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (4 measurements)
Micro-perforated acrylic glass sound absorber: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC63 Hz80 Hz100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
5 mm · 100 mm · Lochdurchmesser 0,55 mm, Lochabstand 3,5 mm0.550.130.120.120.250.350.400.500.930.910.930.700.600.450.390.280.250.220.180.220.08
5 mm · 25 mm · Lochdurchmesser 0,65 mm, Lochabstand 4 mm, Lochflächenanteil 0,0314 %0.350.000.000.000.000.000.020.090.120.250.500.850.930.650.370.200.180.150.080.050.05
5 mm · 50 mm · Lochdurchmesser 0,55 mm, Lochabstand 3,5 mm, Lochflächenanteil 0,0207%0.350.000.000.020.050.100.200.350.600.980.850.700.300.200.150.100.080.050.020.000.00
5 mm · 100 mm · Lochdurchmesser 0,8 mm, Lochabstand 6 mm, Lochflächenanteil 0,0140 %0.350.050.080.200.300.450.850.980.800.400.300.200.150.100.080.020.050.200.020.000.00
Measured values as a table (4 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated: