Glass & transparentBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: J.Meyer, Kirchenakustik, Verlag E.Bochinsky

Value from the PTB table, not verified

Micro-perforated glass panels

PTB reference data

Original description

Micro-perforated glass panels

Material properties

Wall distance: 2 in

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.45
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.450.850.300.100.05

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.45 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Micro-perforated glass panels: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
5 cm0.450.100.450.850.300.100.05