MetalHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: DNA-Tabelle 1968, b2.2-7
Value from the PTB table, not verified
Metal baffle ceiling with mineral fiber panel backing
PTB reference data
Original description
Metal baffle ceiling with mineral fiber panel backing
Material properties
Thickness: 0 in + baffle curvature
Wall distance: 14 in
Surface weight: 3.2 kg/m
Backing: 0.8 in mineral fiber panel, surface-treated on room side
Flow resistance: 90 kPa·s/m²
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.90
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|
| αp | 0.90 | 0.85 | 0.90 | 0.85 | 0.70 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.90 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz | 5000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 0,3 mm + Lamellenwölbung · 356 mm | 0.90 | 0.85 | 0.78 | 0.99 | 0.88 | 0.88 | 0.75 | 0.85 | 0.88 | 0.92 | 0.97 | 0.92 | 0.88 | 0.82 | 0.70 | 0.70 | 0.68 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: