Stone & concreteBroadband absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: DNA-Tabelle 1968, b3-2

Value from the PTB table, not verified

Facing brick masonry with mineral fiber infill

PTB reference data

Original description

Facing brick masonry with mineral fiber infill

Material properties

Thickness: 2.2 in
Wall distance: 2 in
Dimensions: 230 x 50 x 2.2 in
Backing: 2 in mineral fiber panels, 100 kg/m³
Flow resistance: 20 Rayl

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.40
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.550.700.300.200.350.35

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.40 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Facing brick masonry with mineral fiber infill: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
55 mm · 50 mm0.400.300.530.780.850.740.500.330.270.230.200.200.210.280.340.400.380.340.340.32
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account