WoodHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 213

Value from the PTB table, not verified

M+G slotted panel made of plywood/fiberboard

M + G slotted panel

PTB reference data

Original description

M+G slotted panel made of plywood/fiberboard

Material properties

Manufacturer: Meyer + Gerber
Thickness: 3 - 0.2 in
Backing: fiber absorber
Surface: color-sprayed or paintable, veneer of choice

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.85
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.350.700.900.950.900.75

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.85 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
M+G slotted panel made of plywood/fiberboard: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
3 - 6 mm · Der Schallschluckgrad ist von der Art and Stärke des hinterlegten Absorptionsmaterials sowie der freien Schlitzfläche abhängig0.850.250.340.450.600.710.800.850.920.930.950.960.950.920.900.850.790.730.70
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated:

See also