Knauf P 142 acoustic plaster, gypsum-bound

Knauf Akustikputz – P 142

NRC 0.35–0.40

PTB reference data
With a free account
Plaster & sprayHigh-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Manufacturer data www.knauf.de

Value from the PTB table, not verified

Original description

Knauf P 142 acoustic plaster, gypsum-bound

Material properties

Manufacturer: Knauf Headquarters Iphofen
Wall distance: 0 in, 2.4 in
Fire class (EN 13501-1): A1
Application: ceiling
Mounting: directly on solid ceiling; on gypsum board ceiling facing

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 2 variants

NRC
0.40

Frequency values

Create a permanent free account. Access frequency bands, variants and export.

Free. No password required.

CompareValue
2.4 in, on Deckenbekleidung from GipsplattenNRC0.40
0, direkt on MassivdeckeNRC0.35

NRC: 0.40 (derived from ISO 354 lab data)

Weight / density: ca. 3 kg / m² at 0.59 in Schichtdicke

Terms of use
Measured values as a table (2 measurements)
Knauf P 142 acoustic plaster, gypsum-bound: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
ca. 3 kg / m² at 0.59 in Schichtdicke · 0, direkt on Massivdecke0.350.030.040.040.060.090.120.190.240.310.370.430.520.610.720.810.981.061.01
ca. 3 kg / m² at 0.59 in Schichtdicke · 2.4 in, on Deckenbekleidung from Gipsplatten0.400.110.190.170.170.150.150.180.210.250.330.420.500.600.720.810.991.011.03
Measured values as a table (2 measurements)

Access frequency bands, variants and export. Create a permanent free account

Last updated:

Calculate reverberation time with this product

See also