Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 3 variants

NRC
0.75

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.650.900.700.800.750.55

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
14 inNRC0.75
3.1 inNRC0.70
6.7 inNRC0.75

NRC: 0.75 (derived from ISO 354 lab data)

Weight / density: ca. 15 - 25 kg / m²

Dimensions: 625 x25 in

Terms of use
Measured values as a table (3 measurements)
Isover Acoustic Panel XAN gypsum cassette ceiling: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz
30mm · ca. 15 - 25 kg / m² · 80 mm0.700.100.140.200.270.430.630.850.940.980.930.800.690.640.660.720.570.500.52
30mm · ca. 15 - 25 kg / m² · 170 mm0.750.400.330.500.600.730.880.930.840.850.780.690.770.740.660.640.500.360.39
30mm · ca. 15 - 25 kg / m² · 350 mm0.750.510.700.800.950.820.860.800.670.700.780.770.790.780.730.720.590.490.50