MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Perforated metal ceiling panel backed with fiberglass

IAC Mark III

PTB reference data

Original description

Perforated metal ceiling panel backed with fiberglass

Material properties

Manufacturer: Industrial Acoustics Company
Thickness: 2 inches, 3 inches
Wall distance: 16 in
Backing: fiberglass
Application: ceiling

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 2 variants

NRC
0.95

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.650.701.001.001.001.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
2 inches1.8 lb/ft²NRC0.95
3 inches3.1 lb/ft²NRC1.00

NRC: 0.95 (derived from ISO 354 lab data)

Dimensions: 24 x 48 inches

Distance: 16 in

Terms of use
Measured values as a table (2 measurements)
Perforated metal ceiling panel backed with fiberglass: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
2 inches · 1.8 lb/ft² · 400 mm0.950.630.710.981.111.031.08
3 inches · 3.1 lb/ft² · 400 mm1.000.560.841.161.160.920.82
Measured values as a table (2 measurements)