MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Manufacturer data www.luxalon.com

Value from the PTB table, not verified

Hunter Douglas Luxalon 84 R perforated aluminum panels (series 2)

Luxalon 84 R

PTB reference data

Original description

Hunter Douglas Luxalon 84 R perforated aluminum panels (series 2)

Material properties

Manufacturer: Hunter Douglas
Thickness: 0 in
Wall distance: 6.3 in
Hole size: 0.1 in
Backing: acoustic non-woven facing
Application: ceiling

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.75
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.350.750.850.650.650.60

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.75 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Hunter Douglas Luxalon 84 R perforated aluminum panels (series 2): sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC100 Hz125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz5000 Hz6300 Hz
160 mm · Deckenpaneele · gelocht0.750.150.370.500.650.810.850.860.910.780.720.650.640.670.700.640.600.580.550.52
Measured values as a table (1 measurement)