MetalHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 171
Value from the PTB table, not verified
Hunter Douglas Luxalon 300 A/S, perforated metal panels
Luxalon 300 A, 300S
PTB reference data
Original description
Hunter Douglas Luxalon 300 A/S, perforated metal panels
Material properties
Manufacturer: Hunter Douglas
Thickness: 0 in aluminum or 0 in galvanized steel
Perforation: 15%
Hole size: 0.1 in
Backing: 1 in mineral fiber
Surface: painted
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.85
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.50 | 0.80 | 0.90 | 0.85 | 0.80 | 0.70 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.85 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mineralwolldichte 22 kg / m³ · Deckenpaneele · gelocht | 0.85 | 0.43 | 0.59 | 0.70 | 0.82 | 0.85 | 0.89 | 0.92 | 0.88 | 0.85 | 0.82 | 0.82 | 0.82 | 0.82 | 0.78 | 0.73 | 0.70 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: