FoamHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 147
Value from the PTB table, not verified
Gummi-Stricker PSST acoustic panel with heavy layer
PSST-Schallabsorptionsplatte mit Schwerschicht – 1422
PTB reference data
Original description
Gummi-Stricker PSST acoustic panel with heavy layer
Material properties
Manufacturer: Gummi-Stricker
Thickness: approx. 0.9 in
Wall distance: 0 in
Backing: 0.8 in polyether foam, 0.1 in thermoplastic layer
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.50
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.15 | 0.20 | 0.50 | 0.65 | 0.60 | 0.50 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.50 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 160 Hz | 200 Hz | 250 Hz | 315 Hz | 400 Hz | 500 Hz | 630 Hz | 800 Hz | 1000 Hz | 1250 Hz | 1600 Hz | 2000 Hz | 2500 Hz | 3150 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ca. 22 mm · ca. 4,3 kg / m² · 0 | 0.50 | 0.13 | 0.15 | 0.18 | 0.20 | 0.28 | 0.40 | 0.50 | 0.58 | 0.61 | 0.67 | 0.65 | 0.63 | 0.62 | 0.59 | 0.54 | 0.50 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: