FoamHigh-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: H. Lenz, Marktübersicht schallabsorbierende Anordnungen, Ruhr Universität Bochum, 1981, Seite 148

Value from the PTB table, not verified

Gummi-Stricker PSST sound absorption panel with heavy layer

PSST sound absorption panel with heavy layer – 1515/20/2

PTB reference data

Original description

Gummi-Stricker PSST sound absorption panel with heavy layer

Material properties

Manufacturer: Gummi-Stricker
Thickness: approx. 0.9 in
Wall distance: 0 in
Backing: 0.1 in thermoplastic layer

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.30
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.150.150.250.600.75

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.30 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Gummi-Stricker PSST sound absorption panel with heavy layer: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz160 Hz200 Hz250 Hz315 Hz400 Hz500 Hz630 Hz800 Hz1000 Hz1250 Hz1600 Hz2000 Hz2500 Hz3150 Hz4000 Hz
ca. 22 mm · ca. 4,2 kg / m² · 00.300.110.120.130.140.140.150.150.190.210.220.380.500.630.670.700.75
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: