Reference surfaceHighly absorbent
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: Dalenbäck, Datensatz der CATT-Software, November 2000. Data-Category in CATT: GYPSUM_DBL, C: Walls, D: Gypsum
Value from the PTB table, not verified
Walls, gypsum board, 2 layers total 32 mm
PTB reference data
Original description
Walls, gypsum board, 2 layers total 32 mm
Material properties
Thickness: 1.3 in
Application: wall
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.15
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.30 | 0.10 | 0.10 | 0.15 | 0.15 | 0.10 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.15 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| Measurement 1 | 0.15 | 0.28 | 0.12 | 0.10 | 0.17 | 0.13 | 0.09 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account
Last updated: