Reference surfaceLow absorption

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: M. Heckl, H.A. Müller: Taschenbuch der Technischen Akustik, Springer 1994

Value from the PTB table, not verified

Drywall panel, 18 mm, 16 kg/m², 400 mm wall distance

PTB reference data

Original description

Drywall panel, 18 mm, 16 kg/m², 400 mm wall distance

Material properties

Thickness: 0.7 in
Wall distance: 16 in
Surface weight: 16 kg/m²

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.05
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.100.100.050.050.050.05

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.05 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Drywall panel, 18 mm, 16 kg/m², 400 mm wall distance: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
18 mm · 16 kg/m^2 · 400 mm0.050.100.090.050.050.070.04
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: