Reference surfaceLow-frequency absorber

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Dalenbäck, Datensatz der CATT-Software, November 2000. Data-Category in CATT: CEIL_PLASTER, C: Ceilings, D: Plasterboard

Value from the PTB table, not verified

Drywall ceiling on battens with large air cavity

PTB reference data

Original description

Drywall ceiling on battens with large air cavity

Material properties

Wall distance: large air cavity
Application: ceiling
Mounting: on battens

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
0.10
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.200.150.100.100.050.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.10 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Drywall ceiling on battens with large air cavity: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
large air-space · plasterboard ceiling on battens0.100.200.150.100.080.040.02
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account

Last updated: