Reference surfaceLow-frequency absorber
Data source
PTB reference data
Physikalisch-Technische Bundesanstalt
Source: JASA 104 (6) Dec 1998
Value from the PTB table, not verified
Plaster ceiling, 60 mm with lighting & ventilation
PTB reference data
Original description
Plaster ceiling, 60 mm with lighting & ventilation
Material properties
Thickness: 2.4 in
Application: ceiling
Mounting: with lighting & ventilation
Measurement data
Sound absorption
Reverberation chamber (ASTM C423 / ISO 354)
NRC
0.05
derived from ISO 354 lab data
Frequency values
αp nach ISO 11654
| f (Hz) | 125 | 250 | 500 | 1k | 2k | 4k |
|---|---|---|---|---|---|---|
| αp | 0.10 | 0.10 | 0.05 | 0.05 | 0.05 | 0.00 |
Create a permanent free account — Access frequency bands, variants and export.
Free. No password required.
Value from the PTB table, not verified
NRC: 0.05 (derived from ISO 354 lab data)
Measured values as a table (1 measurement)
| Build-up | NRC | 125 Hz | 250 Hz | 500 Hz | 1000 Hz | 2000 Hz | 4000 Hz |
|---|---|---|---|---|---|---|---|
| 60 kg/m² | 0.05 | 0.10 | 0.08 | 0.05 | 0.04 | 0.03 | 0.02 |
Measured values as a table (1 measurement)
Access frequency bands, variants and export. Create a permanent free account