MetalHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: C.M.Harris, Noise Control in Buildings, McGraw Hill 1994

Value from the PTB table, not verified

Perforated steel panel backed by 4 inch layer of 2 pcf OCF Type R-23 Fiberglas

PTB reference data

Original description

Perforated steel panel backed by 4 inch layer of 2 pcf OCF Type R-23 Fiberglas

Material properties

Manufacturer: Commercial Acoustics
Thickness: 4 1/4 inch
Wall distance: 0 in
Density: 2 pcf
Backing: 4 inch layer of 2 pcf OCF Type R-23 Fiberglas

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

NRC
1.10
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.851.001.001.001.001.00

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 1.10 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Perforated steel panel backed by 4 inch layer of 2 pcf OCF Type R-23 Fiberglas: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
4 1/4 inch · 5 lb/ft² · 01.100.861.091.221.061.051.04
Measured values as a table (1 measurement)

Access frequency bands, variants and export. Create a permanent free account