Mineral woolHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: Manufacturer data

Value from the PTB table, not verified

Ecophon Master C/alpha glass wool panel with Akutex T surface

Ecophon – Master C/alpha

PTB reference data

Original description

Ecophon Master C/alpha glass wool panel with Akutex T surface

Material properties

Manufacturer: Ecophon GmbH
Thickness: 1.6 in
Wall distance: 1.6 in, 7.9 in
Surface: Akutex T coating, non-woven faced, color-coated edges

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)· 2 variants

NRC
0.95

Frequency values

αp per octave band

f (Hz)1252505001k2k4k
αp0.200.751.001.000.950.95

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

CompareValue
tKh = 1.6 in (totale Konstruktionshöhe)NRC0.95
tKh = 7.9 in (totale Konstruktionshöhe)NRC0.85

NRC: 0.95 (derived from ISO 354 lab data)

Weight / density: ca. 5,5 kg / m²

Dimensions: 600 x 24 in, 625 x 25 in

Application: for gute Akustik and Sprachverständlichkeit, z.B. Schulen, Großraumbüros usw.

Terms of use
Measured values as a table (2 measurements)
Ecophon Master C/alpha glass wool panel with Akutex T surface: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC63 Hz125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
40 mm · ca. 5,5 kg / m² · tKh = 40 mm (totale Konstruktionshöhe) · for gute Akustik and Sprachverständlichkeit, z.B. Schulen, Großraumbüros usw. · Akutex T0.950.200.751.001.000.950.95
40 mm · ca. 5,5 kg / m² · tKh = 200 mm (totale Konstruktionshöhe) · for gute Akustik and Sprachverständlichkeit, z.B. Schulen, Großraumbüros usw. · Akutex T0.850.200.500.750.800.950.950.95
Measured values as a table (2 measurements)