Reference: audienceHighly absorbent

Data source

PTB reference data

Physikalisch-Technische Bundesanstalt

Source: J.Meyer, Kirchenakustik, Verlag E. Bochinsky

Value from the PTB table, not verified

Occupied pews (churches), 2 persons/m²

PTB reference data

Original description

Occupied pews (churches), 2 persons/m²

Material properties

No further information available.

Measurement data

Sound absorption

Reverberation chamber (ASTM C423 / ISO 354)

Values per m² of audience area, not per chair or person.

NRC
0.75
derived from ISO 354 lab data

Frequency values

αp nach ISO 11654

f (Hz)1252505001k2k4k
αp0.200.400.800.900.900.90

Create a permanent free accountAccess frequency bands, variants and export.

Free. No password required.

Value from the PTB table, not verified

NRC: 0.75 (derived from ISO 354 lab data)

Terms of use
Measured values as a table (1 measurement)
Occupied pews (churches), 2 persons/m²: sound absorption coefficient αs per ISO 354 by frequency and test build-up
Build-upNRC125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz
2 Pers. / m² · besetzt0.750.220.400.800.900.900.90
Measured values as a table (1 measurement)